R911271002 is part of the HVR Power Supply Units Series by Indramat Power Supplies.
Use
DIAX04 control systems
Power output (peak)
75 kilowatts
Power output (continuous)
25 kilowatts
DC bus voltage
750 Volts
Power output (short-term)
60 kilowatts
Regenerative power (peak)
75 kilowatts
Regenerative power (continuous)
25 kilowatts
Maximum regenerated energy
80 kilowatts
Bleeder peak power
120 kilowatts
Internal DC bus capacity
1.2 millifarad
External DC bus capacity
20 millifarad
Power loss at max continuous power output
750 Watts
Basic power loss
150 Watts
Power loss per kilowatt DC bus continuous power
24 Watts per kilowatt
Approximate shipping weight
21 kilograms
Cooling
Integrated blower
Operating temperature range
5 to 45 degrees Celsius
Recommended installation altitude
Up to 1000 meters
Power supply AC voltage range
380 to 480 Volts AC (±10%)
Line frequency range
50 to 60 Hertz