R911271002 (HVR02.1-W025N)
HVR Power Supply Units
Technical Specifications
Use
DIAX04 control systems
Power output (peak)
75 kilowatts
Power output (continuous)
25 kilowatts
DC bus voltage
750 Volts
Power output (short-term)
60 kilowatts
Regenerative power (peak)
75 kilowatts
Regenerative power (continuous)
25 kilowatts
Maximum regenerated energy
80 kilowatts
Bleeder peak power
120 kilowatts
Internal DC bus capacity
1.2 millifarad
External DC bus capacity
20 millifarad
Power loss at max continuous power output
750 Watts
Basic power loss
150 Watts
Power loss per kilowatt DC bus continuous power
24 Watts per kilowatt
Approximate shipping weight
21 kilograms
Cooling
Integrated blower
Operating temperature range
5 to 45 degrees Celsius
Recommended installation altitude
Up to 1000 meters
Power supply AC voltage range
380 to 480 Volts AC (±10%)
Line frequency range
50 to 60 Hertz
Frequently Asked Questions
What is the rated power output of HVR02.1-W025N?
The HVR02.1-W025N delivers 25 kW of power output.
What type of cooling method is used in HVR02.1-W025N?
The HVR02.1-W025N uses internal air cooling with a built-in blower.
What is the peak power capacity of HVR02.1-W025N?
The HVR02.1-W025N can provide a 60 kW peak power.
What is the input voltage range for HVR02.1-W025N?
The HVR02.1-W025N operates at 3 x AC 380–480 V (±10%).
What is the maximum regenerated energy supported by HVR02.1-W025N?
The HVR02.1-W025N supports 100 kWs of regenerated energy.
Common Misspellings
HVR021W025N
HVR02 1 W025N
hvr02.1-w025n
HVR2.1-W025N
Internal Product Review
The HVR02.1-W025N provides 25 kW of output power, ensuring a smooth and regulated DC supply for advanced drive systems. With a reliable cooling mechanism and high regeneration capacity, it balances energy efficiency with durability, thus ideal for heavy-duty production environments.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HVR02.1-W025N.
Exchange
Want to sell your HVR02.1-W025N?