HVR Power Supply Units
Technical Specifications
Design
Line 3, Design 1
Use
DIAX04 Chassis
Continuous Output Power Rating
75 kilowatts
Peak power(10 sec)
100% of rated
Peak power(3 sec)
200% of rated
Peak power(0.3 sec)
300% of rated
DC Bus Peak Output
135 kilowatts
DC Bus Short Time Power
104 kilowatts
Regen Energy Max
80 kilowatts
Regen Power Continuous
45 kilowatts
Regen Power Peak
90 kilowatts
Cooling Mode
Convection Cooling
Dimensions
498 x 250 x 262 millimeters
Weight
31 kilogram
Display
Two-place display
Replacement
Identical unit required
Repairs
By Bosch Rexroth
Location of Type Plate
Top side of power supply unit.
Frequently Asked Questions
What type of cooling system does the HVR03.1-W045N/S025 use?
The HVR03.1-W045N/S025 uses internal air cooling with a built-in blower.
What is the rated power output of the HVR03.1-W045N/S025?
The HVR03.1-W045N/S025 delivers 45 kW of output power.
What is the peak power of the HVR03.1-W045N/S025?
The HVR03.1-W045N/S025 provides 135 kW peak power.
What is the input voltage range for the HVR03.1-W045N/S025?
The HVR03.1-W045N/S025 operates on 3 x AC 380–480 V (±10%).
What is the maximum regenerated energy of the HVR03.1-W045N/S025?
The HVR03.1-W045N/S025 regenerates up to 100 kWs of energy.
Common Misspellings
HVR031W045NS025
HVR03 1 W045N S025
hvr03.1-w045n/s025
HVR3.1-W045N/S025
Internal Product Review
The HVR03.1-W045N/S025 delivers exceptional 45 kW output and 135 kW peak power, ensuring smooth energy flow in high-demand operations. Its internal air cooling enhances stability, making it a reliable choice for heavy automation processes requiring continuous performance.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HVR03.1-W045N/S025.
Exchange